+91 88830 77955 sales@niproweitek.com Coimbatore · Chennai · Tiruchirappalli · Bangalore · Kochi
Mon–Sat, 9:30 AM – 5:00 PM
Load Cells

Fully Digital Load Cell

Digital load cell with built-in signal processing, self-diagnostics and anti-tamper protection.

  • OIML R60 C3 accuracy class
  • RS485 digital output, IP68
  • Anti-tamper and self-diagnostics
Fully Digital Load Cell by Nipro Weitek
Overview

About the Fully Digital Load Cell

Fully digital load cells are designed for weighing accuracy, enhanced security and intelligent performance in modern industrial weighing systems. Built-in digital signal processing and diagnostics give stable, tamper-resistant measurements while simplifying installation, calibration and maintenance.

Each load cell communicates digitally over an RS485 bus, so individual cell readings can be monitored and faults pinpointed without opening the junction box.

Need a price or a recommendation?

Share your requirement and our sales engineers will respond with the right configuration and a quotation.

Key features

What you get

High-precision digital weighing technology for stable, consistent measurements

Anti-tamper and anti-hacking protection against signal manipulation and fraudulent weight alterations

Self-diagnostics with fault detection that continuously monitors load cell performance

Long service life with minimal maintenance thanks to durable materials

Factory calibrated with internal temperature and drift compensation

Plug-and-play set-up with auto calibration — no manual trimming

Cable break and overload detection

Technical data

Specifications

Technical specifications

ParameterUnitOIML R60 C3
Rated outputcounts1,000,000
Maximum capacity (Emax)t10, 20, 25, 30, 40SE, 40, 50
Max. number of load cell intervalsnLC3000
Ratio of min. LC verification intervalY = Emax/Vmin15000 / 7500
Combined error% FS≤ ±0.023
Minimum dead loadof Emax0%
Safe overloadof Emax150%
Ultimate overloadof Emax300%
Zero balanceof FS< ±1.5%
Excitation, recommended voltageV6 ~ 12
Excitation, maximumV18
Communication interface—RS485 / 6-wire
Communication baud ratebps19200
Number of bus addresses—Max 32
Compensated temperature°C−10 ~ +40
Operating temperature°C−35 ~ +65
Storage temperature°C−40 ~ +90
Element material—Nickel-plated alloy steel
Ingress protection (EN 60529)—IP68
ATEX classification (optional)—II 1G Ex ia IIC T4 · II 1D Ex iaD 20 T73°C · II 3G nL IIC T4

Dimension drawings are available on request.

Model DES3 — double ended shear beam (30 t / 40 t)

ParameterSpecification
Capacity30 t, 40 t
TypeDouble ended shear beam
MaterialNickel alloy steel
Digital output signalRS-485, 4 wire
Ingress protectionIP68
Creep error (30 minutes)±0.020% FS
Zero balance±1% FS
Maximum safe overload150% FS
Recommended excitation voltage5 – 15 V DC
Nominal temperature range−10 to +40 °C
Operating temperature range−20 to +70 °C
ConstructionHermetically sealed, integrated surge protectors, built-in microcontroller and A/D converter
ApplicationWeighbridges

Minimum order 6 pieces. Supplied ex-stock or within 7 days.

Installation

Site & installation requirements

  • Fits weighbridge platforms using the matching mounting accessories.
  • Digital addressing on the RS485 bus lets each load cell be identified and diagnosed from the indicator.
  • No long analogue cable runs — the signal stays digital from the load cell to the indicator.
How our installation and maintenance works
FAQ

Questions about this product

Each cell converts its signal inside the load cell and sends it digitally, so it is far less affected by cable length, interference and tampering, and every cell can be monitored and diagnosed individually.

Fully digital load cells are available from 10 t to 50 t, including the DES3 double ended shear beam model in 30 t and 40 t.

The minimum order for the DES3 model is 6 pieces, supplied ex-stock or within 7 days.

Analogue strain gauge load cells output a millivolt signal that is combined in a junction box and read by the indicator. Digital load cells convert the signal inside each cell and communicate over RS485, so every cell can be monitored individually, faults are easier to locate and the signal is more resistant to tampering and interference.

Yes. Share the weighbridge make, capacity, number of load cells and indicator model. Our service team will confirm a compatible replacement or recommend upgrading the weighbridge to digital load cells, then install and recalibrate it.

The capacity per load cell, quantity, application (weighbridge, tank, silo or process), the indicator or controller it connects to, and any hazardous-area (ATEX) requirement.
Related
Get a quote

Enquire about the Fully Digital Load Cell

Tell us about your application. Approximate figures are fine — our engineers will confirm the right configuration with you.

  • Response from our sales team
  • Configuration advice for your site
  • Installation and service support included in the discussion

Prefer to talk?

+91 88830 77955 · WhatsApp

Product enquiry

* Required

We use your details only to respond to this enquiry. See our privacy policy.

Ready to discuss your load cells requirement?

Our engineers can recommend the right configuration and share a detailed quotation.

Chat with us on WhatsApp (opens in a new tab)